Int J Hyperthermia. 2015 Jun 5:1-7.


High intensity focused ultrasound ablation for submucosal fibroids: A comparison between type I and type II.


Xie B, Zhang C, Xiong C, He J, Huang G, Zhang L.


Department of Ultrasound, Huanggang Central Hospital , Huanggang City, Hubei , China .



OBJECTIVE: The aim of this study was to compare high-intensity focused ultrasound (HIFU) treatment for type I 
and type II submucosal fibroids.?


MATERIALS AND METHODS: From October 2011 to October 2013, 55 patients with submucosal fibroids were enrolled 
in this study. Based on submucosal fibroid classification, 27 patients were grouped as type I submucosal 
fibroids, and 28 patients were classified as type II submucosal fibroids. All patients received HIFU 
treatment and completed 1-, 6-, and 12-month follow-ups. Adverse effects were recorded.?


RESULTS: There were no significant differences in the baseline characteristics between the two groups (p?>?
0.05). Using similar sonication power, sonication time, and acoustic energy, the non-perfused volume (NPV) 
ratio was 83.0?±?17.3% in the type I group, and 92.0?±?9.5% in the type II group. All the patients tolerated the 
procedure well, and no serious adverse events occurred. During the follow-up intervals, the treated fibroids 
shrank and fibroid-related symptoms were relieved. No other reinterventional procedures were performed during 
the follow-up period.


CONCLUSION: Based on our results with a small number of subjects, HIFU is suitable for both type I and type 
II submucosal fibroids. It seems that type II submucosal fibroids are more sensitive to HIFU ablation. Future 
studies with larger sample sizes and longer follow-up times to investigate the long-term results, including 
long-term symptom relief, pregnancy outcomes, and the recurrence rate as well as the reintervention rate are 
needed.


PMID: 26044873


출처: http://www.ncbi.nlm.nih.gov/pubmed/?term=26044873





점막하근종에 하이푸치료: 타입1과 타입2의 비교


목적: 하이푸치료에 있어 타입1과 타입2의 점막하근종을 비교 연구하기 위함 


재료와 방식: 2011년 10월부터 2013년 10월까지 55명의 점막하근종이 이번 연구에 대상이었다. 점막하근종 분류에 기초하여 27명의 환
자들은 타입1, 28명의 환자들은 타입2로 분류되었다. 모든 환자들은 하이푸치료를 받았고 1, 6, 12개월 추적관리를 하였다. 부작용도 
기록되었다.

결과: 치료전 두그룹 유의하 중요한 차이는 없었다. 초음파분해에 있어 비슷한 출력, 시간, 음향에너지를 사용하여 비관류용적은 그룹1에
서 83%, 그룹2에서 92%를 보였다. 모든 환자들은 치료를 잘 견뎠고 심각한 부작용도 없었다. 추적관리하는 기간에 치료된 근종은 축소
되었다. 그리고 치료된 근종으로 인한 증상도 경감되었다. 추적관리하는 기간동안 다른 부가적인 중재적시술은 필요하지 않았다.??


결론: 우리의 연구의 결과에 기초하여 하이푸는 타입1과 타입2근종 치료에 적합하다. 타입2근종은 하이푸치료에 더 민감하게 반응하는 것
으로 보인다. 대단위 연구, 장기적인 결과 평가를 위해 장기적 결과, 장기적 증상 경감, 임신 결과, 재발율에 관한 향후 연구가 필요하
다.


     
 
         